Universal Hexadecimal Counter (ECL)The MC10136 is a high speed synchronous counter that can count up, countdown, preset, or stop count at frequencies exceeding 100 MHz. The flexibility of this device allows the designer to use one basic counter for most applications,and the synchronous count feature makes the MC10136 suitable for either computers or instrumentation.
Three control lines (S1, S2, and Carry In-bar) determine the operation mode of the counter. Lines S1 and S2 determine one of four operations; preset(program), increment (count up), decrement (count down), or hold (stop count).Note that in the preset mode a clock pulse is necessary to load the counter, and the information present on the data inputs (D0, D1, D2, and D3) will be entered into the counter. Carry Out-bar goes low on the terminal count, or when the counte ris being preset.
This device is not designed for use with gated clocks. Control is via S1 and S2.
Features:- PD = 625 mW typ/pkg (No Load)
- fcount = 150 MHz typ
- tpd = 3.3 ns typ (C-Q)
- 7.0 ns typ (C-Cout)
- 5.0 ns typ (Cin-Cout)
|